Manual valves for manual shut-off, for gas and air, UL listed and CSA approved.
DN: 10 to 50
connection: thread
pe: max. 125 psig (8.8 bar) brass housing
Product Literature
AKT Product Brochure
AKT Technical Information

Gas filter with polypropylene fleece filter pad for cleaning gas and air.
DN: 15 to 100
connection: NPT thread or ANSI flange
pe: max. 15 or 60 psig (1 or 4 bar)

Gas filter with polypropylene fleece filter pad for cleaning gas and air.
DN: 15 to 100
connection: NPT thread or ANSI flange
pe: max. 15 or 60 psig (1 or 4 bar)

Spring-loaded pressure regulator with inlet pressure compensation diaphragm and zero shut-off, for maintaining a constant set outlet pressure pa when gas throughput fluctuates.
DN: 15 to 100
connection: NPT thread or ANSI flange
pe: max. 15 or 60 psig (1 or 4 bar)
pa: 2 "WC to 5 psig (5 to 350 mbar)

Spring-loaded pressure regulator with inlet pressure compensation diaphragm and zero shut-off, for maintaining a constant set outlet pressure pa when gas throughput fluctuates. GDJ for gas, GDJ..L for air.
DN: 15 to 50
connection: NPT thread
pe: max. 5 psig (350 mbar)
pa: 1 to 64 "WC (2 to 160 mbar)

Spring-loaded pressure regulator with inlet pressure compensation diaphragm and zero shut-off, for maintaining a constant set outlet pressure pa when gas throughput fluctuates.
DN: 15 to 10
connection: NPT thread or ANSI flange
pe: max. 15 or 60 psig (1 or 4 bar)
pa: 2 "WC to 5 psig (5 to 350 mbar)
Product Literature
VGBF Technical Information

Spring-loaded pressure regulator with inlet pressure compensation diaphragm and zero shut-off, for maintaining a constant set outlet pressure pa when gas throughput fluctuates.
DN: 15 to 100
connection: NPT thread or ANSI flange
pe: max. 15 or 60 psig (1 or 4 bar)
pa: 2 "WC to 5 psig (5 to 350 mbar)
Product Literature
VGBF Technical Information

Gas/air ratio regulators for maintaining a constant gas/air pressure ratio of 1:1, GIK, GI for continuous control, GIK..B for high/low/off control.
DN: 15 to 100
connection: NPT thread or ANSI flange
pe: max. 3 psig (200 mbar)
pL: 0.2 to 48 "WC (0.5 to 120 mbar)
pG: 0.08 to 47.6 "WC (0.2 to 119 mbar)
Δp: max. 1.5 psig (100 mbar)
Product Literature
GIK Operating Instructions

JSAV: Safety overpressure shut valve to secure all downstream fittings against too high gas pressure, for gas.
DN: 25 to 100
connection: thread or flange
pe: max. 60 psig (4 bar)
pso: 7.5 "WC to 8 psig (18 to 550 mbar)
Product Literature
JSAV Brochure
JSAV Operating Instructions

JSAV: Safety overpressure shut valve to secure all downstream fittings against too high gas pressure, for gas.
DN: 25 to 100
connection: thread or flange
pe: max. 60 psig (4 bar)
pso: 7.5 "WC to 8 psig (18 to 550 mbar)
Product Literature
JSAV Brochure
JSAV Operating Instructions

JSAV: Safety overpressure shut valve to secure all downstream fittings against too high gas pressure, for gas.
DN: 25 to 100
connection: thread or flange
pe: max. 60 psig (4 bar)
pso: 7.5 "WC to 8 psig (18 to 550 mbar)
Product Literature
JSAV Brochure
JSAV Operating Instructions

Variable gas/air ratio regulators for maintaining a constant gas/air pressure ratio of 4:1 on systems with air pre-heating, GIKH for continuous control, GIKH..B for high/low/off control.
DN: 25 and 40
connection: NPT thread
pe: max. 3 psig (200 mbar)
p: max. 1.5 psig (100 mbar)
pL: 0.06 to 12 "WC (0.15 to 30 mbar)
pG: 0.08 to 48 "WC (0.2 to 120 mbar)
Product Literature
GIK Operating instructions

Butterfly valves to set the flow rate of air on gas burners, prepared for attachment of a gear motor GT, for regulation ratios up to 1:10, with angle-of-rotation indicator.
DN: 25 to 150,
for fitting between two flanges
pe: max. 120 "WC (300 mbar),
with manual adjustment, with square shaft for mounting a gear motor GT or with free shaft end,
max. medium temperature: 212°F (100°C) disc with clearance
Product Literature
DKL Brochure

Butterfly valves to set the flow rate of air on gas burners, prepared for attachment of a gear motor GT, for regulation ratios up to 1:10, with angle-of-rotation indicator.
DN: 25 to 150, for fitting between two flanges
pe: max. 120 "WC (300 mbar),
with manual adjustment, with square shaft for mounting a gear motor GT or with free shaft end
max. medium temperature: 212°F (100°C) disc with clearance.
Product Literature
DKL Brochure

Gas valves for automatic shut-off, closed when de-energized, for gas and air, FM approved.
DN: 15 to 80
connection: NPT thread or ANSI flange
pe: max. 2 or 5 psig (130 or 360 mbar)
quick opening, quick closing or slow opening, quick closing
mains voltage: 120 V AC
electrical connection: terminals
The following versions are available:
valves with flow adjustment
valves for closed position indicator assembly
valves for visual indicator assembly
Product Literature
VGP Brochure

Gas valves for automatic shut-off, closed when de-energized, for gas and air, FM approved.
DN: 15 to 80
connection: NPT thread or ANSI flange
pe: max. 2 or 5 psig (130 or 360 mbar)
quick opening, quick closing or slow opening, quick closing
mains voltage: 120 V AC
electrical connection: terminals
The following versions are available:
valves with flow adjustment
valves for closed position indicator assembly
valves for visual indicator assembly
Product Literature
VG Brochure
VG Operating Instructions

Gas valves for automatic shut-off, closed when de-energized, for gas and air, FM approved.
DN: 15 to 80
connection: NPT thread
or ANSI flange
pe: max. 2 or 5 psig (130 or 360 mbar)
quick opening, quick closing or slow opening, quick closing
mains voltage: 120 V AC
electrical connection: terminals
The following versions are available:
valves with flow adjustment
valves for closed position indicator assembly
valves for visual indicator assembly
Product Literature
VG Brochure
VG Operating Instructions

Solenoid valves for air, for high/low control, for cold-air operation on industrial burners, UL and CSA approved.
DN: 40 to 65
connection: NPT thread
pe: max. 2 psig (130 mbar)
quick opening, quick closing or slow opening, slow closing
mains voltage: 120 V AC
electrical connection: terminals with flow adjustment
The following versions are available:
valves with position indicator
valves with bypass orifice
Product Literature
VR Brochure
VR Operating Instructions

Diaphragm pressure switch with micro-switch for monitoring gas pressures in industry, for gas and air, also for biologically produced methane, with hand wheel for switching point adjustment, FM and UL approved.
Switching ranges: 0.2 to 200 "WC (0.5 to 500 mbar)
DG..T for positive pressure, negative pressure and differential pressure
electrical connection: terminals or standard plug with socket
The following versions are available:
pressure switch with gold-plated contacts for voltages < 30 V
pressure switch with control lamp
pressure switch with external adjustment
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Diaphragm pressure switch with micro-switch for monitoring gas pressures in industry, for gas and air, also for biologically produced methane, with hand wheel for switching point adjustment, FM and UL approved.
Switching ranges: 0.2 to 200 "WC (0.5 to 500 mbar)
DG..HT locks off with rising pressure
DG..NT locks off with falling pressure
electrical connection: terminals or standard plug with socket
The following versions are available:
pressure switch with gold-plated contacts for voltages < 30 V
pressure switch with control lamp
pressure switch with external adjustment
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Diaphragm pressure switch with micro-switch (silicone-free) for monitoring gas pressures on industrial installations and OEM heating systems, for positive pressure, for gas, also for biologically produced methane, variable hand wheel switching point adjustment, UL listed.
Switching ranges: 8 to 120 "WC (2 to 300 mbar)
with external thread: 1/4" NPT or 1/8" NPT, thread with sealant
electrical connection: standard socket, with change-over contact
The following versions are available:
pressure switch with gold-plated contacts for voltages < 24 V
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Diaphragm pressure switch with micro-switch for monitoring air pressures in industry and trade, for positive pressure, negative pressure and differential pressure, for air and flue gas, FM and UL approved.
Switching ranges: 0.08 to 20 "WC (0.2 to 50 mbar)
DL..ET with tube connection and switching point set at factory
electrical connection: AMP plug, terminals or standard sockets
The following versions are available:
pressure switch with gold-plated contacts for voltages < 30 V
pressure switch with control lamp
pressure switch with external adjustment
pressure switch with angle bracket
Product Literature
DL Brochure

Diaphragm pressure switch with micro-switch for monitoring air pressures in industry and trade, for positive pressure, negative pressure and differential pressure, for air and flue gas, FM and UL approved.
Switching ranges: 0.08 to 20 "WC (0.2 to 50 mbar)
DL..AT with threaded and tube connection and hand wheel for switching point adjustment
electrical connection: AMP plug, terminals or standard sockets
The following versions are available:
pressure switch with gold-plated contacts for voltages < 30 V
pressure switch with control lamp
pressure switch with external adjustment
pressure switch with angle bracket
Product Literature
DL Brochure

Gas safety valves for automatic shut-off, closed when de-energized, for gas and air, FM and ETL approved.
Size: 1 to 3
DN: 15 to 50
connection: MODULINE system
pe: max. 2 or 5 psig (140 or 360 mbar)
quick opening, quick closing or slow opening, quick closing
mains voltage: 120 V AC
electrical connection: terminals
Accessories:
Visual indicator
Closed position indicator
Product Literature
VS Brochure

Gas safety valves for automatic shut-off, closed when de-energized, for gas and air, FM and ETL approved.
Size: 1 to 3
DN: 15 to 50
connection: MODULINE system
pe: max. 2 or 5 psig (140 or 360 mbar)
quick opening, quick closing or slow opening, quick closing
mains voltage: 120 V AC
electrical connection: terminals
Accessories:
Visual indicator
Closed position indicator
Product Literature
VS Brochure

For safeguarding and control of gas pressures in gas inlet and burner lines, for gas and air, FM and ETL approved.
GVS: universal governor
GVI: air/gas ratio control for maintaining a constant gas/air ratio
size: 1 to 3
DN: 15 to 50
connection: MODULINE system
pe: max. 2 psig (140 mbar)
mains voltage: 120 V AC
electrical connection: terminals

Inlet flanges with or without strainer for pipes: 3/8 to 2 NPT
Outlet flanges for pipes: 3/8 to 2 NPT
Filter and strainer modules for intermediate fitting, for protecting downstream devices.
Orifice modules for adjusting the maximum flow rate to the respective combustion process.
Connecting sets consisting of screws, nuts and sealing ring, for connecting two MODULINE controls.
Intermediate element with threaded connections 1/2 to 1/4 NPT for ignition gas branch and pressure gauge connection.
Attachment bracket 1/4 NPT for locked installation of pressure gauges and other accessories.

Inlet flanges with or without strainer for pipes: 3/8 to 2 NPT
Outlet flanges for pipes: 3/8 to 2 NPT
Filter and strainer modules for intermediate fitting, for protecting downstream devices.
Orifice modules for adjusting the maximum flow rate to the respective combustion process.
Connecting sets consisting of screws, nuts and sealing ring, for connecting two MODULINE controls.
Intermediate element with threaded connections 1/2 to 1/4 NPT for ignition gas branch and pressure gauge connection.
Attachment bracket 1/4 NPT for locked installation of pressure gauges and other accessories.

Inlet flanges with or without strainer for pipes: 3/8 to 2 NPT
Outlet flanges for pipes: 3/8 to 2 NPT
Filter and strainer modules for intermediate fitting, for protecting downstream devices.
Orifice modules for adjusting the maximum flow rate to the respective combustion process.
Connecting sets consisting of screws, nuts and sealing ring, for connecting two MODULINE controls.
Intermediate element with threaded connections 1/2 to 1/4 NPT for ignition gas branch and pressure gauge connection.
Attachment bracket 1/4 NPT for locked installation of pressure gauges and other accessories.

Safety time for start-up: 3, 5 or 10 s
safety time for operation: 1 or 2 s
mains voltage: 230 V AC or 115 V AC, for earthed or unearthed mains
Automatic burner control unit, ignition transformer, Manual/Automatic mode and display of operating and fault statuses in a metal housing, for controlling and monitoring gas burners, for continuous operation with ionisation control, for intermittent operation with UV control (with UV sensors of type UVS) or as a variant for continuous operation with UV control (with UV sensor UVD 1), single-electrode operation possible, setting of various operating modes via optical interface using separate software, FM approved.
BCU 460 for directly ignited burners of unlimited capacity, with air valve control (optional).
BCU 465 with extended air control.
BCU 480 for pilot and main burners of unlimited capacity, with air valve control.

Flame detector for multi-flame control in conjunction with IFS 110IM or for flame signalling, for intermittent operation, ionization or UV control, FM approved.
For grounded or non grounded mains
mains voltage: 110/120 V AC
Product Literature
IFW 15 Brochure
IFW 15 Operating Instructions

Flame detector in 19" standard rack for multi-flame control in conjunction with PFS or for flame signalling.
PFF 704: for intermittent operation
ionization or UV control, FM approved. With 4 independent flame amplifiers
mains voltage: switchable from 220/240 V AC to 110/120 V AC, for grounded or non grounded mains
Product Literature
PFF 704 Operating Instructions

Automatic burner control units for controlling and monitoring gas burners,
for intermittent operation, ionization or UV control. Single-electrode operation possible, multi-flame control possible, for earthed mains, FM and CSA approved.
For grounded mains:
main gas after safety time, fault lock-out or restart following flame failure
trial for ignition period: 3, 5 or 10 s, flame failure response time for V2: 1 or 2 s
flame failure response time for V1: 1 or 2 s
mains voltage: 110/120 V AC
Product Literature
IFS 110IM Brochure
IFS 110IM Operating Instructions

Automatic burner control units for controlling and monitoring gas burners, for intermittent operation, ionization or UV control, cut-off threshold for flame current variable, measuring sockets for uninterrupted flame current measurement, single-electrode operation possible, signal contacts for operation and faults, FM and CSA approved.
Immediate fault lock-out or restart following flame failure
trial for ignition period: 3, 5 or 10 s
flame failure response time: 2 s
mains voltage: 110 V AC, 115 V AC, 200 V AC or 230 V AC, for grounded or non grounded mains
Product Literature
IFS 258 Brochure

Automatic burner control units in 19" standard rack for controlling and monitoring gas burners, for intermittent operation, ionization or UV control, FM approved.
PFS 778: main gas after safety time or main gas after flame proving period, switchable for continuously controlled burners, single-electrode operation possible,
PFS 748: main gas following flame signal for burners in intermittent operation high/low
restart or immediate fault lock-out
following flame failure
switchable air valve control possible
multi-flame control possible
trial for ignition period: 3, 5 or 10 s
flame failure response time for V2: 2 s
flame failure response time for V1: 2 s
mains voltage: switchable from 220/240 V AC to 110/120 V AC, for grounded or non grounded mains,
controlled by standard 24 V DC signals.

Relay card for 19" standard rack, for signal coupling, FM approved.
Controlled by 24 V DC/AC, 110/120 V AC or 220/240 V AC.
With 4 independent relays.
Product Literature
PFP 700 Operating Instructions

Power supply in 19" standard rack for supplying the control inputs on automatic burner control units PFS, FM approved.
Output rating: 24 V DC, 600 mA,
mains voltage: switchable from 220/240 V AC to 110/120 V AC.
Product Literature
PFP 700 Operating Instructions

Burners with cast steel housing, connection for ceramic tube provided.
Burner size: 50 to 140
capacity: 34,000 to 1,228,000 BTU/h
(10 to 360 kW)
flame shape: normal flame or long, soft flame
gas type: natural gas, town gas or LPG
length of burner tube: depending on ceramic tube
connection:
gas: thread
air: thread or flange
The following versions are available: burner with integrated ignition lance.
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Burners with cast steel housing, connection for ceramic tube provided.
Burner size: 50 to 140
capacity: 34,000 to 1,228,000 BTU/h
(10 to 360 kW)
flame shape: normal flame or long, soft flame
gas type: natural gas, town gas or LPG
length of burner tube: depending on ceramic tube
connection:
gas: thread
air: thread or flange
The following versions are available: burner with integrated ignition lance
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Burners with cast steel housing, steel burner tube.
Burner size: 50 to 140
capacity: 137,000 to 1,536,000 BTU/h
(40 to 450 kW)
flame shape: normal flame, long, soft flame or short, flat flame
gas type: natural gas, town gas or LPG
length of burner tube: 2 to 40" (50 to 1000 mm)
connection:
gas: thread
air: thread or flange
The following versions are available: supply, burner with integrated ignition lance
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Burners with steel-plate housing, steel burner tube.
Burner size: 165 to 200
capacity: 2,150,000 to 3,413,000 BTU/h (630 to 1000 kW)
flame shape: normal flame, long, soft flame or short, flat flame
gas type: natural gas, town gas or LPG
length of burner tube: 2 to 40" (50 to 1000 mm)
connection:
gas: thread
air: flange
The following versions are available:
burner with integrated ignition lance
Product Literature
DG Brochure
DG Operating Instructions
DG Technical Information

Recuperator burner for indirectly or directly heated furnace systems.
Burner size: 65/50, 80/65, 100/80
Capacity: 70,000 to 280,000 BTU/h (21 to 82 kW)
flame shape: long, soft flame
gas type: natural gas or LPG
length of burner tube: depending on ceramic tube
connection:
gas: thread
air: thread
max. furnace temperature: 950°C
Product Literature
BICR Technical Information

Pilot burner with one ignition/monitoring electrode for safe ignition of gas burners in conjunction with automatic burner control units IFS or PFS, with forced air supply.
Capacity: 2,800 to 11,500 BTU/h (0.8 to 3.4 kW)
gas type: natural gas, town gas
or LPG
length of burner tube: 6 to 38" (150 to 1000 mm)
connection: NPT thread

For all applications requiring precise temperature control and consistent product quality. The BIC..L burner is perfectly designed for use in the tunnel kilns and intermittent systems as used in the ceramics industry. A single burner type enables you to follow all the temperature profile requirements of the kiln. Thanks to the high excess air capability of up to approx. 1500% high flue gas temperatures of up to approx. 100°C can be reached in near-stoichiometric burner operation with maximum excess air. With reliable ignition over the entire burner output range this accommodates the furnace operator's wish for a simple structured gas/air control.
Burner size: 80, 100 and 140
capacity: 256,000, 512,000 and 1,024,000 BTU/h (75, 150 and 300 kW)
gas type: natural gas or LPG
length of burner tube: depending on ceramic tube
connection: thread or flange
Product Literature
BIC Operating Instructions

Pilot burner with forced air supply for safe ignition of gas burners in conjunction with automatic burner control units IFS or PFS.
Capacity: 68,000 BTU/h (20 kW), gas type: natural gas, town gas or LPG
length of burner tube: 4 to 38"
(100 to 1000 mm)
connection: thread

Pilot burner with forced air supply for safe ignition of gas burners in conjunction with automatic burner control units IFS or PFS.
Capacity: 6830 to 23900 BTU/h (2 to 7 kW)
gas type: natural gas, town gas
or LPG
length of burner tube: 6/4 to 40/4 inch (150/100 to 1000/100 mm)
connection: thread
Product Literature
ZKIH Operating Instructions

UV detectors for monitoring gas burners, FM approved
UVS 6: with connection terminals, with integrated heat protection, IP 55

UV detectors for monitoring gas burners, FM approved
UVS 8: with non-detachable silicone cable, with integrated heat protection, IP 40

Turbine wheel meters for measuring gas flow on gas consumption equipment, for gas burner adjustment, for gas and air.
DM: mechanical counter head
measuring range: 50 to 35000 ft3/h
connection: thread or installation between two flanges
pe: max. 175 psig (12 bar)
Product Literature
DM Brochure
DM Operating Instructions

Turbine wheel meters for measuring gas flow on gas consumption equipment, for gas burner adjustment, for gas and air.
DM: mechanical counter head
measuring range: 50 to 35000 ft3/h
connection: thread or installation between two flanges
pe: max. 175 psig (12 bar)
Product Literature
DM Brochure
DM Operating Instructions

Turbine wheel meters for measuring gas flow on gas consumption equipment, for gas burner adjustment, for gas and air.
DE: electronic counter head
measuring range: 50 to 35000 ft3/h
connection: thread or installation between two flanges
pe: max. 175 psig (12 bar)
Product Literature
DM Brochure
DM Operating Instructions

Pressure gauges with capsule elements and Bourdon tubes for pressure display, resistant to positive pressure, with zero point correction, for gas and air.
Measuring ranges:
KFM: 0 to 5 psig (0 to 400 mbar)
diameter: 63 or 100 mm

Pressure gauges with capsule elements and Bourdon tubes for pressure display, resistant to positive pressure, with zero point correction, for gas and air.
Measuring ranges:
RFM: 0 to 230 psig (0 to 16 bar)
diameter: 63 or 100 mm

The appropriate differential pressure can be checked using two pressure test points before and after the orifice.

Manual valves for manual shut-off, for gas and air, UL listed and CSA approved.
DN: 10 to 50
connection: thread
pe: max. 125 psig (8.8 bar) brass housing
Product Literature
AKT Product Brochure
AKT Technical Information