Operate with Flame Rod and/or P-C II Scanner
6642 Features
• Modularized Multi-Burner Control
• Time Proven Plug-in Solid State FLAME-PAK
Amplifier
• Plug-in, Interchangeable Relays
• Plug-in Power Transformer
• Flame Rod and/or Ultra-Violet Sensing.
Independent or simultaneously using
same FLAME-PAK Amplifier.
Form 6642VA
• Basic combustion safeguard model
Form 6642VB
• Breaker – lockout switch model
• Required for automatic lighted
installations. System “latches out” after
failure to light within ignition trial time
and cannot attempt restart until switch is
manually reset.
• Standard ignition trial time is 15 seconds.
Also available in 10-second and 5-second
trial time.
• Form 6642VBNR – Automatic only and
Non-relight.
Form 6642VL
• Load relay – included for all multi-burner
models
Form 6642VT
• Timofier model plugin, fixed time
assembly.
• The timofier provides purge time and
ignition trial time. The ignition trial time is
deducted from the motor time cycle
(1/2, 1, 1-1/4, 2, 3, 4, and 6 minutes
available for manual and automatic
models; 10 minutes for manual model
only) to purge the time.
• Standard ignition trial time is 15 seconds.
Also available in 10-second and 5-second
trial time.
• Specify both purge and ignition times.
• Purge time shall allow system to have a
minimum of four fresh air changes.
Form 6642VBL
• Combines features of Breaker and Load
relay models described above.
• Form 6642VBLNR – Automatic only and
Non-relight.
Form 6642VBT
• Combines features of Breaker and
Timofier models described above.
• Form 6642VBTNR – Automatic only and
Non-relight.
Form 6642VLT
• Combines features of Load relay
and Timofier models described above.
Form 6642VBLT
• Combines features of Breaker, Load relay,
and Timofier models described above.
• Form 6642VBLTNR – Automatic only and
Non-relight.
Form 6642FF
• Full Feature Combustion Safeguard
including:
• Proof of Closure
• Proof of High Fire Purge
• Purge Timing (In 15 sec. increments,
7 min. 45 sec. max)
• Proof of Low Fire Start
• Ignition Trial Timing (Pilot) 10 sec.
• Pilot Interrupt Timing
(Main burner ignition trial) 10 or 15 sec.
• Alarm output if the safety interlocks
(limit switches) or flame failure
causes shutdown.
• Relay contacts available to drive actuator
to high fire for purge, low fire for
ignition trial, and control when main
burner is proven.
• Eight status lights